Stability indicatingmethod for estimation of Amlodipine besylate by RP-HPLC in tablet dosage formand characterization of the oxidation impurity of amlodipine besylate

Pritam S.Jain, ManishK.Patel, Sanjay J.Surana


A simple, specific, accurate and precise stability indicating Reverse Phase High Performance Liquid Chromatographic method was developed for estimation ofAmlodipine besylate in tablet dosage formon RP C18 BDS column (250mm×4.6 mm, 5µm) with a mobile phase consisting of A: Triethylamine (pH 3.0) adjusted with ortho phosphoric acid, B:ACN, with a timed gradient program of T/%B: 0/30, 7/70, 8/30, 10/30 with a flow rate of 1.4 ml/min, UV detection at 236 nmwas used. The retention time forAmlodipine besylate was found to be 4.5min. Proposedmethod was validated for precision, accuracy, linearity, range, robustness, ruggedness and force degradation study. The calibration curve ofAmlodipine besylate was linear over the range of 12.5-37.5 µg/ml. The method was found to be sensitive with limit of detection was determined 0.16 and limit of quantitation was determined 0.49 µg/ml. The oxidative degraded product ofAmlodipine besylate formed was investigated by electrospray ionization (ESI) timeof- flightmass spectrometry, NMR and IR spectroscopy. The found unknown impurity related to oxidative degradationwas 2, 6-dimethyl-3-Ethoxycarbonyl-5-Methoxycarbonyl 1, 4-Dihydropyridine.


மறுப்பு: இந்த சுருக்கமானது செயற்கை நுண்ணறிவு கருவிகளைப் பயன்படுத்தி மொழிபெயர்க்கப்பட்டது மற்றும் இன்னும் மதிப்பாய்வு செய்யப்படவில்லை அல்லது சரிபார்க்கப்படவில்லை

குறியிடப்பட்டது

  • CASS
  • கூகுள் ஸ்காலர்
  • ஜே கேட் திறக்கவும்
  • சீனாவின் தேசிய அறிவு உள்கட்டமைப்பு (CNKI)
  • CiteFactor
  • காஸ்மோஸ் IF
  • எலக்ட்ரானிக் ஜர்னல்ஸ் லைப்ரரி
  • டைரக்டரி ஆஃப் ரிசர்ச் ஜர்னல் இன்டெக்சிங் (DRJI)
  • ரகசிய தேடுபொறி ஆய்வகங்கள்
  • ICMJE

மேலும் பார்க்க

ஜர்னல் எச்-இண்டெக்ஸ்

Flyer